CHP3000 Series 10kva to 30kva UPS power supply

CHP3000 Series 10kva to 30kva UPS power supply

CHP3000 series best backup 10KVA to 30KVA UPS power supply system (3 phase input & 3 phase output) double conversion On-Line ups with an isolation transformer at Output.
Type : CHP3000 Series
Phase : three phase
Power Factor : 0.8
Input voltage : 380VAC+/-25%
Input frequency : 50/60Hz+/-10%
INQUIRY DOWNLOAD PDF Format
Details
Features
Parameters

CHP3000 Brief introduction:


CHP3000 series best backup 10KVA to 300KVA UPS power supply system (3 phase input & 3 phase output) double conversion On-Line ups with an isolation transformer at Output. The Load is supplied continuously by the inverter with clean, stabilized and regulated sine wave output power. Input & Output filters increase the immunity of load from power disturbances and surges.

 

CHP3000 series UPS entirely surmounted the technical bottleneck in analog circuitry age,ingeniously applied the digital control technology and high-accuracy SMD technology which assured ultra-high system stability and is able to fully acclimate various grid environment,Single-machine capacity is ranging from 10KVA and 800KVA, widely used in telecom,bank,bond,traffic,utility,manufacture,etc





CHP3000 Main Features:


  • True On line-Double Conversion Technology.

  • 7 inches LCD+LED Big Screen Display.

  • Stable Rectifier and Harmonic Filters.

  • IGBT PWM Inverter Technology.

  • High Efficiency up to 92%.

  • Wide Input Voltage Range.

  • Advanced Battery Management.

  • Short Circuit and Overload Protection.

  • 256 Real Time Event Log with Detailed Parameters.

  • Static & Manual Bypass Operation.

  • Advanced Communication Capabilities.

  • Perfect Generator Compatibility.

  • Cold Start Function.

  • Auto Restart Function.

  • Can Set ECO Work Mode.

  • Optional EPO Function.



MODELCHP3010KCHP3015KCHP3020KCHP3025KCHP3030K
Capacity10kVA15kVA20kVA25kVA30kVA
Power Watt8kW12kW16kW20kW24kW
Working PrincipleLow Freuqency  Transformer Based True On Line-Double Conversion
RECTIFIER (INPUT)
PhaseThree Phase
Input Power FactorStandard ≧ 0.9 ( 6pulse Rectifier+Filter ),  Optional ≧ 0.96 ( 12pulse Rectifier+Filter)
Input Voltage Range220/380VAC (230V/400VAC or 240V/415VAC)±25% 3P+N+PE    ;      110V/208VAC( 120V/220VAC or  277V/480VAC ) optional
Input Frequency Range50Hz±10% / 60Hz±10% (Selectable)
Total Harmonic Distortion (THDi)6pulse Rectifier<30%, Optional 12pulse Rectifier & Filter<5%
Output Ripple<2%
Soft Start0~100% 5sec
CHARGING
Charging ModeConstant current,then constant voltage, charge with temperature compensation, automatic switch Between Equalized charging and Float charging
Float Charging Voltage432VDC
Equalized Charging Voltage464VDC
Temp. Compensated Voltage-3mV/℃/cell
Charging Current0.1C ( Automatic adjust according to battery capacity)
BATTERY
TypeVRLA/AGM/Gel, optional Lithium Battery
Battery Capacity7~999AH settable (Configurate Battery Capacity according to Back-up Time)
Quantity32units 12V or 192units 2V batteries (Nominal Voltage 384VDC)
Temperature20ºC~25ºC (For Maximum Efficiency)
INVERTER (OUTPUT)
PhaseThree Phase
Rated VoltageRated Capacity*0.9
Nominal Voltage220/380VAC (230V/400VAC or 240V/415VAC), 3P+N   110V/208VAC( 120V/220VAC or  277V/480VAC ) optional
Output Voltage Regulated Accuracy±1%( Stable load), ±3%( fluctuant load)
Output Frequency Range50Hz 60Hz<±0.5% ( Asynchronous )
Crest Factor> 3:1
Output Total Harmonic Distortion (THD)Pure Sine Wave, Linear Load< 3%, Non-Linear Load<5%
Dynamic CharacteristicsInstant voltage<±5% ( from 0 to100% ), Instant recover time<10ms
Unbalanced Load Voltage< ±5%
Overload CapacityAt 115% load, normal work, At 125% load 10 min, At 150% load 1min, At 200% load 1S
Inverter Efficiency>92% ( full load )
BYPASS
Phase3 Phase +N
Input Nominal Voltage220/380VAC (230V/400VAC or 240V/415VAC)     110V/208VAC( 120V/220VAC or  277V/480VAC ) optional
Output Nominal Voltage220/380VAC (230V/400VAC or 240V/415VAC)     110V/208VAC( 120V/220VAC or  277V/480VAC ) optional
Transfer Time0ms( adopt static switch )
PROTECTION FUNCTION
Input ProtectionInput voltage, frequency over limited protection, Phase fault, Phase lack
Output ProtectionOver current, short circuit, over voltage, low voltage
Battery ProtectionOver charge, over-discharge protection
Temperature ProtectionEnvironment over temperature protection, inverter over temperature protection
Hardware Fault ProtectionAssistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc protection
GENERAL SYSTEM PARAMETERS
Working EnvironmentTemp: -10~40ºC, relative humidity: 30%~90%, Altitude<2000m ( 1% decrease against 100 meters’ rise, max. altitude 4000m )
Cooling MethodCOMPULSIVE VENTILATION
Communitation InterfaceRS232/ RS485, optional dry contact, SNMP card ( for remote control via Internet)
Parallel OperationTandem hot backup or parallel connection
Auti-surge Capacity10/700μS, 5KV;  8/20μS, 20KA
Protection LevelIP31
Safety PerformanceVin-n Vout-n 3000Vac, creepage<3.5mA , insulating resistance>2MΩ(500VDC)
Noise (dB)48~55
Dimension (W*D*H) mm600*620*1250
Weight (Kg)205245265285311
※ 200V-208V-220V (Ph-Ph) Version is available
Baykee reserves the right to change or modify product design, construction, specifications or materials without prior notice and without incurring any obligation to make such changes and modifications on Baykee products previously or subsequently sold.