BK11 Series 0.5kva to 10kva emergency power supply

BK11 Series 0.5kva to 10kva emergency power supply

FEPS series BK11 small power single phase emergency power supply, the capacity is from 0.5KVA to 10KVA, This series products adopts high-speed MCU and CPLD, controlled by Software Programming. The power devices adopt the most advanced sixth generation low
Type : BK11 Series
Phase : single phase
Power Factor : 1
Input voltage : 165~242VAC
Input frequency : 50Hz±5%
INQUIRY DOWNLOAD PDF Format
Details
Features
Parameters

EPS Series Brief introduction:


FEPS series BK11 small power single phase emergency power supply, the capacity is from 0.5KVA to 10KVA, This series products adopts high-speed MCU and CPLD, controlled by Software Programming. The power devices adopt the most advanced sixth generation low losses high power IGBT and static switch. The series products is the power supply products with international newest control devices and the advanced software, is a dedicated power supply which is applied to fire emergency equipments. 


EPS Series Main Features:


  • Screen cabinet design, intuitionistic big screen LCD with Chinese, English display, LED status indication.

  • The flow diagram running status visual display, intelligent icon touch button, tabular data display, events records display, Chinese and English optional menu operation.

  • Inverter back-up work mode design, high speed static transfer switch.

  • Intelligent digital control technology.

  • High-efficiency IGBT(Insulated Gate Bipolar Transistor)inverter technology.

  • Excellent load feature.

  • It completely meet load step from 0-100% while no need change to bypass, and make sure the output stable, reliable

  • High-powered dynamic feature.

  • Adopt kinds of feedback control such as instantaneous control mode and virtual value, not only realize the high dynamic adjustment, but also reduce the output voltage distortion.

  • Adopt 6 pulse rectifier charger, Intelligent battery management.

  • Selectable battery inspection module.

  • Can measure single parameter and display on the LCD, Battery failure will immediately alarm and inform the administrator.

  • Intelligent detecting function.

  • This system microprocessor can continually online detect power status, the breaker status and all the working status. Like meeting the faults, EPS immediately protect, alarm and notice the administrator.

  • Intelligent communication interface.

  • With RS232 and RS485 standard collocation, optional SNMP, selectable dry connector, adopt non-source contactor to reach the monitor of the EPS.

 


Model0.5KVA1KVA1.5KVA2KVA2.5KVA3KVA3.7KVA4KVA5KVA6KVA7KVA8KVA9KVA10KVA
Nominal Capacity(KVA)0.511.522.533.745678910
Input voltage frequency165~242VAC,50Hz±5%
Emergency output voltage, frequency220V±3%,50Hz±0.5%
Emergency output wave formsine wave, distortion factor<3%(linear load)
Dynamic characteristicsDynamic transient range <±10%(from 0 to100% ), transient recover time<20mS
Overload Protectionover load 120% normal running, over load 150%  immediately protect  
Transfer Time<1ms(Static Switch, switch), the biggest time<5s, can manually transfer
Efficiencyemergency power supply>90%, main power supply ~closed to 100%
transfer functionmanual and automatic transfer function
Linkage control functionExternal access 24 V linkage control signal, turn to emergency power supply mode
Mandatory startstart mandatory start switch, work in the emergency mode, meantime close battery low voltage protection
protectionoutput short circuit/overload/over voltage, low voltge/ over temperature etc. protections, Default Phase can run, with Audible and visual alarm.
displayLED display: Mains indicate (Green), Emergency indicate (Red), charge indicate(Red) and faults indicate(yellow)
LCD display: input/output voltage, output current, inverter voltage, frequency, output current, battery pack voltage, temperature work mode, flow diagram, current work status, events records and systems information etc.
AlarmImitate mains faults, battery low voltage, temperature faults, breakers break off etc.faults, check voice alarm(mute silence function) and status indicate
Running environmentTemperature -25℃~55℃
Relative humidity0~90%
charge functionbasically complete to battery charge in 24 hours and again discharge, it reach above rated time *80%
insulated Resistanceinput/output to ground insulated Resistance >=5MΩ
withstand voltageBetween input/output and shell withstand frequency 50*(1+-0.01)Hz, voltage 1250*(1+-0.1)V for 60s+-5s, shouldn’t happen surface fly arc or breakdown phenomenon
leakage currentWhen 1.06 times nominal voltage works, the leakage current<=0.5mA
Battery typemaintenance-free sealed acid battery
nominal battery voltage48VDC
charge voltage55VDC220VDC (automatically Equalized Charging once every 3 months, charge voltage 232VDC)
battery low voltage protection43.2VDC172.8VDC
discharge time90min
battery static  dischargestatic discharge current<=10-5C20A
Computer Communication InterfaceRS232/RS485
Cooling down methodCOMPULSIVE VENTILATION
Noise(dB)(according to load and temperature) 1M away from the machine 40~60
Size W×D×H(Unit:mm)600×250×880
weight(kg)60636870757778798083168169170171