HTT Series 10kva to 200kva online UPS

HTT Series 10kva to 200kva online UPS

BAYKEE HTT series high frequency online UPS system, adopt double conversion online type, which is an optimum design for all power failure. This design can effectively protect the loads from surges, meanwhile, ensure output stability, accuracy, reliability
Type : HTT Series
Phase : three phase
Power Factor : 0.9
Input voltage : 291~492V@100%Load
Input frequency : 35Hz~70Hz
INQUIRY DOWNLOAD PDF Format
Details
Features
Parameters

HTT Brief introduction:


BAYKEE HTT series high frequency online UPS system, adopt double conversion online type, which is an optimum design for all power failure. This design can effectively protect the loads from surges, meanwhile, ensure output stability, accuracy, reliability power to the loads. This series products adopt all digital control technology, can reach parallel redundancy function, to provide our customer more flexible, future expansion and safety guarantee. 




HTT Main Features:


  • Three phase input& output true online

  • Double DSP+double CPLD all digital accurate operation control

  • Input power factor up to 0.99, system efficiency>96%

  • Input THDi<5%, output voltage regulation accuracy < +/-1%

  • 200V-482V wide input range, all loads compatible

  • Supper Over load capacity and short circuit protection

  • Digital parallel redundancy tech,multi-parallel, full reliability

  • Three stage charging, battery each set numbers 30~50 units optional (even) external battery lifeModular design, average maintenance 10 min

  • EPO function 


Model HTT-10KVAHTT-15KVAHTT-20KVAHTT-30KVAHTT-40KVAHTT-60KVAHTT-80KVAHTT-100KVAHTT-120KVAHTT-150KVAHTT-200KVA
Capacity  10KVA/10KW15KVA/15KW20KVA/20KW30KVA/30KW40KVA/40KW60KVA/60KW80KVA/80KW100KVA/100KW120KVA/120KW150KVA/150KW200KVA/200KW
Mains input(AC )










Phase3 phase +N+PE
Voltage range291~492 V(line-line) full load; 200V~291V linearly decrease
Frequency range 35Hz~70Hz
THDi<3% (full linear load)
Power factor0.995
Bypass range -10%~10% (can customized -10%~-30%, +10%~+20%)
Battery










Connection typepositive series and negative series battery
Rated voltage +/- 240VDC (positive and negative each 20pcs*12V series), can customized
Battery number 40pcs/set (can customize 30~50pcs/set even optional)
Charging current 20% system power (battery capacity)
Output(inverter)










Output voltage380VAC 3 phase+N+PE
Voltage regulation  <+/-1%
Phase lock range 50Hz/60Hz+/-5Hz(self frequency 50Hz/60Hz+/-0.01Hz)
Output frequency50Hz/60Hz+/-0.01(turn into mains frequency if phase locked)
Power factor1
Crest factor 3:1
THDu  THD<2.0% (linear load), THD<3%(non-linear load)
Three phase voltage unbalance degreebalance load: 0.5%  100% unbalance load : 1%
Dynamic voltage transient range<3%
Transient Recorery Time   0ms
Three phase voltage deviationmains:0.4;  battery :0.3
Transfer timemains to battery: 0ms;  inverter to bypass: 0ms
Overload capacity125% for 10min: 150% for 1min; >150% for 200ms (linear load)
System efficiency >96% >95%
Environment indicator










Noise <65dB @100%load, cooling fan adopt intelligent speed control
Displaytouch screen LCD+LED
Interfacestandard: RS232, RS485, dry contacts, SNMP card optional
Operation temperature temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C         Altitude(m): <1000, 1000m-2000m above every 100m reduce 1%
IP classIP30( Removable dust filter)
Physical specifications










Cabinet size (W*D*H) 420*750*880600*800*1250600*1100*2000
Cabinet weight KG7070758085210230235250415460
Modules No.(Max)










NOTES:  subject to change without further notice!