MP1100 Series 1kva to 3kva online UPS

MP1100 Series 1kva to 3kva online UPS

MP1100 series UPS uninterruptible power supply system is the new generation transformer based true online double conversion full digital controlled UPS.
Type : MP1100 Series.
Phase : single phase
Power Factor : 0.9
Input voltage : 200VAC
Input frequency : 50/60Hz+/-10%
INQUIRY DOWNLOAD PDF Format
Details
Features
Parameters

MP1100 Series Brief introduction:


MP1100 series UPS uninterruptible power supply system is the new generation transformer based true online double conversion full digital controlled UPS. This series UPS adopts high-speed microprocessor (MCU), Programmable logic device (CPLD) program which are controlled by software, the sixth generation low-exhaust and big-power IGBT and static switch as power components. This series product combines the world’s newest control spare parts and the most advanced software. It is designed to meet high availability and high power quality needs of a wide variety of critical applications

MP1100 is widely used in telecom, bank, security, transporting, utility, manufacture, industry, commerce, government, medical equipment etc.


MP1100 Series Main Features:


  • LED+LCD display, make the operation easier via LCD panel.

  • Low frequency true online double-conversion technology.

  • Wide input voltage range, compatible with different utilities.

  • Advanced digital circuit system design, increase the ups stability.

  • Advanced & Intelligent battery management, extend the battery life.

  • Intelligent inspection system, inspect all kinds of ups work status.

  • High precision SMD technique, improve the circuit reliability and running precision.

  • IGBT PWM inverter technology, provide the highest quality output power, efficiency is higher to 92%.

  • Static bypass operation, provide safe failure to mains if ups is overloaded or develops a fault.

  • Manual bypass operation, make the technical personnel work on faulty UPS, safe to change the inner units.256 real time event log with detailed parameters.

  • Standard RS232 & RS485, optional dry contacts or SNMP card for remote control.

  • Excellent load characters, Fulfill saltus from 0-100% without switching to bypass, safeguard stable output.Input & output voltage, battery charge &

  • discharge, temperature, short Circuit and overload etc. protections.

  • Can Choose UPS, ECO, or Inverter Work Mode.

  • Auto restart function.

  • Perfect generator compatibility.

  • Optional EPO function.

  • Optional battery detecting module.

 



MODELMP1101KMP1102KMP1103KMP1104KMP1106KMP1108KMP1110KMP1115KMP1120KMP1130K
Capacity1kVA2kVA3kVA4kVA6kVA8kVA10kVA15kVA20kVA30kVA
Power Watt0.8kW1.6kW2.4kW3.2kW4.8kW6.4kW8kW12kW16kW24kW
Working PrincipleLow Freuqency  Transformer Based True On Line-Double Conversion
RECTIFIER (INPUT)
PhaseSingle Phase
Input Power Factor≧0.9 ( Plus Filter)
Input Voltage Range220VAC (230VAC or 240VAC)±25% , 1P+N+PE   optional 110V(120V or 277V )
Input Frequency Range50Hz±10% / 60Hz±10% (Selectable)
Output Ripple<2%
Soft Start0~100% 5sec
CHARGING
Charging ModeConstant current, then constant voltage, and charge with temperature compensation                                                            
Float Charging Voltage55VDC220VDC
Equalized Charging Voltage56.8VDC227VDC
Temp. Compensated Voltage-3mV/℃/cell
Charging Current5-10A
BATTERY
TypeVRLA/AGM/Gel, optional Lithium Battery
Battery Capacity7~999AH settable ( Configurate Battery Capacity according to Back-up Time )
Quantity4units 12V or 24units 2V batteries   ( Battery Voltage 48VDC)16units 12V or 96units 2V batteries (Battery Voltage 192VDC)
Temperature20ºC~25ºC (For Maximum Efficiency)
INVERTER (OUTPUT)
PhaseSingle Phase
Nominal Voltage220VAC (230VAC or 240VAC), 1P + N   optional 110V(120V or 277V )
Output Voltage Regulated Accuracy±1 %( Stable load), ±3%( fluctuant load)
Output Frequency Range50Hz 60Hz<±0.5% ( Asynchronous )
Crest Factor> 3:1
Output Total Harmonic Distortion (THD)Pure Sine Wave, Linear Load < 3%, Non-Linear Load<5%
Dynamic CharacteristicsInstant voltage<±5% ( from 0 to100% ), Instant recover time<10ms
Overload CapacityAt 115% load, normal work, At 125% load 10 min, At 150% load 1min, At 200% load 1S
Inverter Efficiency>92% ( full load )
BYPASS
PhaseSingle Phase ( P+N )
Nominal Voltage220VAC (230VAC or 240VAC)   optional 110V(120V or 277V )
Transfer Time0ms( adopt static switch )
PROTECTION FUNCTION
Input ProtectionInput voltage, frequency over limited protection
Output ProtectionOver current, short circuit, over voltage, low voltage
Battery ProtectionOver charge, over-discharge protection
Temperature ProtectionEnvironment over temperature protection, inverter over temperature protection
Hardware Fault ProtectionAssistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc. protection
GENERAL SYSTEM PARAMETERS
Working EnvironmentTemp: -10~40ºC, relative humidity: 30%~90%, Altitude<2000m ( 1% decrease against 100 meters’ rise, Max. altitude 4000m )
Cooling MethodCOMPULSIVE VENTILATION
Communitation InterfaceRS232/ RS485, optional dry contact, SNMP card ( for remote control via internet )
Parallel OperationTandem hot backup
Auti-surge Capacity10/700μS, 5KV;  8/20μS, 20KA
Protection LevelIP21
Safety PerformanceVin-n Vout-n 2000Vac, creepage<10mA , insulating resistance>2MΩ(500VDC)
Noise (dB)45~5050~5555~6055~60
Dimension (W*D*H) mm210*520*530220*520*640220*500*760450*600*1200
Weight (Kg)42525959658492186201251
※100V-110V-120V Version is available
Baykee reserves the right to change or modify product design, construction, specifications or materials without prior notice and without incurring any obligation to make such changes and modifications on Baykee products previously or subsequently sold.